WT-9001 IP65 GSM Remote Control And Alarm System
WT-9001 IP65 USER MANUAL Rev. 3.4 Technical Support: technical@witura.com
COPYRIGHT ©2008 WITURA CORPORATION SDN BHD
To turn on input number 1, you can send the following text message to the unit.
*CTR1#1
Sending the following SMS Message to unit would mean input 1 will be turned off
*CTR1#0
The 1 indicates the ON command and the 0 (zero) indicates the OFF command
Every input can generate text alerts to all 20 of the administrator’s Mobile phone
numbers and this function can be changed at any time by sending the following
commands by SMS message to the unit.
Text Command:
*RER[N]#X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X,X;
N stands for input number 1 - 8
X stands for position for 1 - 20 administrators with function value: 0 (OFF), 1 9
(number of text alerts)
Example 1:
Any alarm coming from Input 1 will generate 2 SMS to administrators 1, 2, 3 and 1 SMS
to the rest, you would send the following SMS message to the unit.
*RER1#2,2,2,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1;
Example of Returned Message:
RER1=2,2,2,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1,1;
Example 2:
Any alarm coming from Input 2 will generate 3 SMS to administrator 1, 2 SMS to
administrator 2, 3, 4 and 5, no SMS to the rest, you would send the following SMS
message to the unit.
*RER2#3,2,2,2,2,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0;
Example of Returned Message:
RER2=3,2,2,2,2,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0;